Intelligent, Safe and Efficient Tailored Industrial LED Lighting OEM/ODM Specialist 
Service Hotline +86 0755-2306 6948
You are here:Home >> Products >> Marine Lighting

Products

Products

Contact Us

Tel: 0086-755-2306 6948
Fax: 0086-755-6164 1072
Zip Code: 518125
Email: info@DUALRAYS.com
10th Floor | Litong Semiconductor Industry Park | Shapuwei Community ,Songgang Town,Bao‘an Dist | Shenzhen 518103,Guangdong Province,RPC

Marine Lighting

TW5 Portable LED Temporary Work Light

The TW5 light is a revolutionary model of portable, temporary
work lighting intended for use in the marine industry, shipbuilding,
ship repair and maintenance, offshore, oil and gas and 
construction industries.
Due to its low, safe operating voltages AC/DC24~42VAC,
AC/DC110V, it can reliably and safely be used during various
technological phases and work processes - steelwork,
sandblasting, high-pressure wash and anti-corrosion protection.
It is made of high-quality robust materials that make them very
resistant without the risk of damage or breakage. IP67 protection
level and mechanical protection IK10.
Compared to traditional work lamps, it is very practical and easy
to use, and makes your service and processes cheaper, faster
and more competitive.
The lighting system contributes to increased productivity and
safety of workers in accordance with the CENELEC norm HD63751
and increased efficiency of all work processes.
The lamp have a very simple connection to the power supply, it
can be connected to 3 types of cable - 2 *1.5/2.5mm² for short lines
and 2*6mm²for longer lines with a bigger number of lamps connected
in a series.
The cable connection is located at the top cover, strong and resistant
to shocks and pulls.

  • Options:
    > 2*1.5mm2 or 2*2.5mm2 wiring-through Optional;
    > Ceiling mounted, Suspension, Magnetic Mounted, Rotatable Wall Mounted;
    > Various intelligent control: 1-10V, Emergency;
    > AC24-42V, AC100-240V 50/60Hz, DC85-285V input voltage optional;

    > Special military operations;
    > Military training camps;
    > War and civil shelters;
    > Temporary settlements, campfire and tents;
    > Storage below or above ground;
    > Rescue operations;
    > Outer and inner areas without lighting;




                                                                     

    General System

    Housing Material                              Extruted PC/PMMA according to the UNE-EN ISO 21305-1:2020 standard, UV filter conditional(IK10)

    Diffuser Material                               Extruted PC/PMMA according to the UNE-EN ISO 21305-1:2020 standard, UV filter conditional(IK10)

    Housing Color                                  White (RAL9016), Other colors optional

    Sealing Gaskets                               Silicone foam

    LEDs Thermal Dissipation               Through finless 6063 AL luminaire body, without conductive fluids. Passive convection dissipation                                                                           ensuring thermal contact with the LED modules through a high-conductivity Lead-free solder paste

    Anti-condensation                             Pressure-balancing valve optional to ensure moisture release, avoid condensation and maintain the luminaire IP tightness

    Finish                                               Electrostatically sprayed and sublimated in the oven. Resistant to corrosion

    Recommended Mounted Height      2 - 4 meters

    Maintenance                                    End-cap with screw for installation

    Driver                                               Constant current, embedded in luminaire, pre-wired

    Dimming Control                              ON-OFF | 1-10V dimming

    IK (Impact Resistance)                     IK10

    Protective Class                               Class ⅠⅠ

    IP (Ingress Protection Rating)          IP67/IP69K

    Glow Wire                                        850°C

    Installation                                       Ceiling mounted | Suspension | Magnetic Mounted | Rotatable Wall Mounted

    Cable Entry                                      Piercing Connector for Flat Cable

    Smart Function                                Microwave Sensor | Emergency

    Luminary Inner Protective Cover     PMMA 2.5mm

    Removable Protective Cover Polycarbonate 2.5 - 3mm


    Electrical System

    Through-wiring                                H05RNH2-F 2*1.5mm2 | 2*2.5mm2 | 2*6.0mm2 wires through for option

    Main Voltage                                   AC/DC24~42V, AC100~240V 50/60Hz, 85-264VDC

    Power Factor (PF)                           ≥0.97

    Total Harmonic Distortion (THD)    <10%

    Output Type                                    Non-SELV(non-isolated)

    Flicker Factor                                 <1%

    Stroboscopic Visibility Measure (SVM)         <0.4                                

    Perceptibility of Stroboscopic Effects (Pst)    <1 

    Terminal Connection                       Piercing Connector for Flat Cable

                                                                    Luminaires Power                     B10A                    B16A                 C10A                   C16A

    Module via LSS Circuit Breakers                   15W                                     94                        145                    130                      210

    Photometry System

    LEDs                                                                 SMD2835 (0.5W)

    CCT (Correlated Color Temperature)                Single CCT (3000K | 4000K | 5000K | 5700K |6500K)

    CRI (Color Rendering Index)                             >80Ra for standard (>90Ra for higher CRI available)

    Photobiological Safety                                      RG0 (exempt of risk)

    EEC (Energy Effciency Class)                           A++

    SDCM (Standard Deviation of Color Matching)      <5 (SDCM<3 Optional)

    UGR (4H, 8H)                                                    24.9 (Cross)

                                                                               23.4 (Longitudinal)               

    Beam Angle                                                       120°/140°/220°/280°/360° Optional

    Average Luminaire Useful Lifetime                   72.000 hours (L80B10)

    Lumen Maintenance at e.o.l.                            >70%

    Luminous Efficacy                                            140LPW (PROLine)

    Related Power                                                  15W

    Lumens Delivered @ 5000K, CRl>80   (PRO)  2.100lm 
    Operation Condition

    Operation Temperature / Humidity                   -20~ +60℃ (-4°F ~ 140°F) / 5~85% RH, not condensed

    Storage Temperature / Humidity                      -40~ +80℃ (-40°F ~ 176°F) / 5~85% RH, not condensed

    Average LED Useful Time L80B10                  ≥100.000H

    Rated Nominal Lifetime (Tp <70℃)                 Up to 100,000H

    Driver MTBF                                                    500.000H,MIL-HDBK-217F(25℃)

    Vibration Resistant                                          10~500Hz,5G 12min / 1cycle,period for 72min. Each along X,Y,Z axes

    Acoustic Noise                                                <25dB (30cm disstance, Normal operation)   

    Guarantee                                                       3 Years (Extensible up to 5 years)


    Certifications

    Global Certificate               ENEC | CE | RoHS | D-mark | KEMA-KEUR Listed, SAA | C-Tick | RCM | CB | ETL/CETL | DLC Premium

    Security Directives             EN 60598-1 | EN 60598-2-3 | EN 62493 | IEC 62471

    EMC Directives                  EN 55015 | EN 61547 | EN 61000-3-2 | EN 61000-3-3 | EN 61347-2-13 | EN 61347-1 | EN 62384

    Other Directives                 IEC 62262 | EN 13032-4 | EN 62717 | EN 6272-1 | EN6272-2-1 | EN 61643-11


    *  Luminous flux tolerance, Power tolerance and color temperature tolerance ±5%, 5000K and CRl>80. 
    *  Lighting beam, light intensity distribution and light efficiency were examined in accordance with the EN ISO 17025:2005 norm for EN13032 norm series and the LM-79 norm.
    *  Up-to-date product info and general warranty terms available on our website www.DUALRAYS.com
    *  Detailed information on luminous fluxes and powers for individual indexes are indicated on the product data sheet.
    *  Values may be subject to change due to LED binning.
    *  The parameters in the data sheet are given for Ta=25°C, based on 4000K/80Ra, 10% efficiency higher with transparent diffuser.



    Ceiling Mounted

      Drilling screw hole on the ceiling.                                        Fix the clip into ceiling with screw.                                        Click into the luminaire by hand tightly

    Suspension


    Drilling screw hole on the ceiling.                                         Click into the luminaire by hand tightly, and                           Click into the luminaire by hand tightly, and 
                                                                                                  then adjust the length of suspension kits.                              then adjust the length of suspension kits.

    Rotatable Ceiling Mounting


    Drilling screw hole on the ceiling.                                        Click into the luminaire with clips.                                           Rotate the angle on demand.




    Magnetic Mounting

    Take out the 2PCS clips with magnetic rings                        Click into the luminaire with magnetic clips                            Fix the luminaire on metallic(Fe, Ni, Co) or its 
    from the component package.                                               with hand tightly.                                                                    alloy objects surface as required.





    Linkable Connection







    Caution:
    Please read all the instructions below before installation: 
    * To avoid electric shock, please ensure that the power supply is turned off before installation.
    * The lamp should be installed and operated by a qualified electrician or technician in accordance with the National Electrical Code and corresponding local codes.
    * Unpack and examine the lamp carefully, report any damage and save all packing materials if anyportion of the product was damaged during transportation.
    * If the lamp is damaged, do not use it!

    Statement:
      According to the International Standard of LED luminaire, here DUALRAYS formally claims that DUALRAYS LED Tri-proof(Weather proof) series
    products isonly allowed to be applied to indoor or semi-outdoor neutral environment. Meanwhile DUALRAYS promises full warranty for the products.

      Any severe environment application including high/low temperature, high humidity, high salinity, high-ammonia etc. is not permitted without the
    official confirmation from the manufacturer. If any misapplication happens, the warranty policy is no longer guaranteed.



  • File Name : Format: Size: Download:
    DUALRAYS Nederland Warehouse 2... PDF 1.05 MB
    DUALRAYS LIGHTING Catalogue 20... PDF 8.65 MB
    DUALRAYS TW5 LED Portable Temp... PDF 1.32 MB
    DUALRAYS LIGHTING Company Pres... PDF 11.99 MB
    DUALRAYS Guarantee Agreement PDF 285.01 KB
    XuYu SMD2835 LM-80 report 6000... PDF 648.10 KB
  • Please submit your contact information to [email protected], Dualraysers will contact you within 24 hours!

    *

    *

    *

    *

    *

Related products